Temperature transmitters provide high accuracy transmission of temperature measurements and are specifically designed for use in nuclear power plants. The transmitters have been seismically qualified to IEEE 344-1975 and 1987, with a design capability to withstand 20G acceleration for the panel mount and 12G for the DIN rail mount.
Performance
|
Input
|
100 or 200 ohm, platinum (consult factory for other ranges)
|
|
Range
|
Wide variety, varies according to model
|
|
Output
|
4 to 20 mA DC
|
|
Accuracy
|
±0.1% calibrated span or ±1°F depending upon the model
|
|
Power Supply
|
Wide range, varies according to model
|
|
Max Load
|
1200 ohms at 48 VDC
|
|
Stability
|
±0.1% calibrated span per 6 months or better (model dependent)
|
|
Temperature Limits
|
Varies according to model
|
|
Seismic
|
IEEE 344
|
|
Environmental
|
IEEE 323
|
|
EMI/RFI
|
MIL-STD 461E (some models)
|
|
Radiation
|
Up to 1 Mrad TID (some models)
|
|
Mounting
|
Panel, DIN rail, Nema 4 or explosion proof depending on model
|
|
Storage
|
In Accordance With ANSI N45.2 Level A
|
|
Shipping Weight
|
1 pound
|
Please use the links below to view the available documentation.
Temperature Transmitters